It can withstand corrosion from some chemistry such as strong acids and alkalis. It withstands shock, and can go from boiling to freezing without shattering. It is vital in processes requiring instant heating or cooling such as distillation or crystallization.
Model |
HRB- 25 |
HRB- 55 |
HRB- 75 |
HRB- A10 |
HRB- A15(W) |
HRB- A25(W) |
HRB- A38W |
HRB- A60W |
|||||||||
Temp range |
0~100 ℃ |
||||||||||||||||
Control accuracy |
±0.5℃ |
||||||||||||||||
Flow control |
2~20L/min |
2~25L/min |
5~50L/min |
||||||||||||||
Heating power |
2.5KW |
5.5KW |
7.5KW |
10KW |
10KW(optional:15KW) |
15KW(optional:25KW) |
25KW(optional:38KW) |
38KW(optional:60KW) |
|||||||||
Cooling capacity (KW) |
100℃ |
2.5KW |
5.5KW |
7.5KW |
10KW |
15KW |
25KW |
38KW |
60KW |
||||||||
20℃ |
2.5KW |
5.5KW |
7.5KW |
10KW |
15KW |
25KW |
38KW |
60KW |
|||||||||
5℃ |
1.8KW |
3.8KW |
5.2KW |
7KW |
11KW |
18KW |
27KW |
42KW |
|||||||||
compressor |
HITACHI |
Emerson Valley Wheel Compressor |
|||||||||||||||
expansion |
Danfoss Thermal Expansion Valve/ Emerson Solenoid |
||||||||||||||||
oil distributor |
Emerson |
||||||||||||||||
Dry filter, Pressure |
Emerson/Danfoss |
||||||||||||||||
Interface size |
G3/4 |
||||||||||||||||
Refrigerant |
R 404A/R507C/R448A |
||||||||||||||||
Dimension cm |
45*85*130 |
55*95*175 |
55*95*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
145*205*205 |
|||||||||
Power max 380V 50HZ |
220V 4.5KW |
8.5KW |
11.5KW |
16KW |
18KW |
28KW |
40KW |
61KW |
|||||||||
Weight kg |
200 |
250 |
280 |
320 |
360 |
620 |
890 |
1300 |
|||||||||
Optional |
220V 60HZ three phase 460V 60HZ three phase |
||||||||||||||||
Optional |
Higher precision control of temperature, flow and pressure |
||||||||||||||||
Optional |
Automatic antifreeze filling system |
||||||||||||||||
Optional |
Automatic liquid recovery system |
Model |
HRB-7.5W/7.5 |
||||
Temperature Range |
-40℃~100℃ antifreeze |
-40℃~100℃ test chamber |
|||
Antifreeze Flow Control |
1L/min~25L/min ±0.2L/min |
/ |
|||
Antifreeze Pressure |
Measure and display the inlet and outlet pressure and display the pressure on the touch screen |
||||
Chamber volume |
Inside the upper box:2200*3220*1200mm Inside the lower box:2200*3220*1100mm |
||||
Heating Capacity |
7.5kW antifreeze |
14kW test chamber |
|||
Cooling Capacity |
135℃ |
7.5kW |
|||
20°℃ |
7.5kW |
||||
0℃ |
7.5kW |
||||
-20℃ |
4.5kW |
||||
-35℃ |
1.8kW |
||||
test chamber |
Heating rate |
25~+100℃≥±2℃/Min |
|||
cooling rate |
25~-40℃≥1℃/Min |
||||
Antifreeze Temp Control Accuracy |
±0.5℃ |
||||
High & low temperature chamber temperature uniformity |
≤2℃ |
||||
Circulation Air Volume |
5000m3/h |
||||
Controller |
PLC controller, fuzzy PID control algorithm |
||||
Communication |
CAN |
||||
Device Internal Temperature Feedback |
The internal temperature of the equipment box, the condensation temperature of the refrigeration system, the suction temperature of the compressor, and the cooling water temperature (with water cooling equipment) |
||||
High temperature cooling module |
Cooling from a high temperature of 100°C |
||||
Circulation pump flow, pressure |
Magnetic drive pump |
||||
Power supply 380V50HZ |
Distribution main air switch model: EZD250E4225ELN |
||||
Dimensions mm |
2400*5600*2850 |
||||
Compressor |
Inverter compressor |
||||
Evaporator |
Plate heat exchanger |
||||
Refrigeration accessories |
Emerson/Danfoss brand dry filter, oil separator, etc. |
||||
Throttling mode |
Electronic expansion valve |
||||
Operation panel |
10-inch color touch screen, temperature curve displayEXCEL data export |
||||
Refrigerant |
R125/R507C/R404A |
||||
Protection |
Phase sequence and phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||
Internal reserved antifreeze interface |
ZG3/4 |
||||
Water cooled condenser |
Jacket/shell and tube heat exchanger |
||||
Cooling water @20°C |
25m3/H |
||||
Load bearing of inner bottom plate (tons) |
1.5 |
||||
Weight (tons) |
4.6 |
||||
Fulfill the standard |
GB/T 2423.1-2008 Test A: Low temperature test method |
||||
GB/T 2423.2-2008 Test B: Low temperature test method |
|||||
GJB 150.3A-2009 High temperature test method |
|||||
GJB 150.4A-2009 High temperature test method |
Model |
HRB-15W/15 |
||||
Temperature Range |
-40℃~100℃ antifreeze |
-40℃~100℃ test chamber |
|||
Antifreeze Flow Control |
1L/min~25L/min ±0.2L/min |
/ |
|||
Antifreeze Pressure |
Measure and display the inlet and outlet pressure and display the pressure on the touch screen |
||||
Chamber volume |
Inside the upper box:2200*3220*1200mm Inside the lower box:2200*3220*1100mm |
||||
Heating Capacity |
15kW antifreeze |
14kW test chamber |
|||
Cooling Capacity |
135℃ |
15kW |
|||
20°℃ |
15kW |
||||
0℃ |
15kW |
||||
-20℃ |
10kW |
||||
-35℃ |
4kW |
||||
test chamber |
Heating rate |
25~+100℃≥±2℃/Min |
|||
cooling rate |
25~-40℃≥1℃/Min |
||||
Antifreeze Temp Control Accuracy |
±0.5℃ |
||||
High & low temperature chamber temperature uniformity |
≤2℃ |
||||
Circulation Air Volume |
5000m3/h |
||||
Controller |
PLC controller, fuzzy PID control algorithm |
||||
Communication |
CAN |
||||
Device Internal Temperature Feedback |
The internal temperature of the equipment box, the condensation temperature of the refrigeration system, the suction temperature of the compressor, and the cooling water temperature (with water cooling equipment) |
||||
High temperature cooling module |
Cooling from a high temperature of 100°C |
||||
Circulation pump flow, pressure |
Magnetic drive pump |
||||
Power supply 380V50HZ |
Distribution main air switch model: EZD400E4350ELK 4P350 |
||||
Dimensions mm |
2400*5600*2850 |
||||
Compressor |
Inverter compressor |
||||
Evaporator |
Plate heat exchanger |
||||
Refrigeration accessories |
Emerson/Danfoss brand dry filter, oil separator, etc. |
||||
Throttling mode |
Electronic expansion valve |
||||
Operation panel |
10-inch color touch screen, temperature curve displayEXCEL data export |
||||
Refrigerant |
R125/R507C/R404A |
||||
Protection |
Phase sequence and phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||
Internal reserved antifreeze interface |
ZG3/4 |
||||
Water cooled condenser |
Jacket/shell and tube heat exchanger |
||||
Cooling water @20°C |
25m3/H |
||||
Load bearing of inner bottom plate (tons) |
1.5 |
||||
Weight (tons) |
4.6 |
||||
Fulfill the standard |
GB/T 2423.1-2008 Test A: Low temperature test method |
||||
GB/T 2423.2-2008 Test B: Low temperature test method |
|||||
GJB 150.3A-2009 High temperature test method |
|||||
GJB 150.4A-2009 High temperature test method |
Model |
HRB-15W |
||||
HRB-15 |
|||||
Temp Range |
-40℃~135℃ Anti-freeze fluid |
-45℃~100℃ Test chamber |
|||
Antifreeze flow control |
2L/min~20L/min ±0.2L/min |
||||
Antifreeze pressure |
Measuring the inlet and outlet pressure and displaying the pressure on the touch screen |
||||
Volume of test chamber |
1000*1000*1000 1m³ |
||||
Heating power |
7.5kW Anti-freeze fluid |
5kW Test chamber |
|||
Refrigerating Output Anti-freeze fluid |
135℃ |
7.5kW |
|||
20℃ |
7.5kW |
||||
0℃ |
7.5kW |
||||
-20℃ |
4.5kW |
||||
-30℃ |
2.5kW |
||||
-35℃ |
1.8kW |
||||
Refrigerating output Test bin |
100℃ |
6kW |
|||
-20℃ |
3.5kW |
||||
-40℃ |
1.2kW |
||||
Temp control precision of antifreeze |
±0.3℃ |
||||
High & low temp cavity temp control |
±0.3℃ |
||||
Test chamber internal circulating air |
3500m3/h |
||||
When the door is opened, the internal circulation fan is automatically closed, and the screen on the touch screen will show that it is in the open state. |
|||||
Controller |
Siemens PLC, Fuzzy PID Control algorithm |
||||
Communicating protocol |
Ethernet Interface TCP/IP Protocol |
||||
Internal temperature feedback |
Equipment tank internal temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured). |
||||
Heat |
The maximum heating output power of the system (according to each model); |
||||
The heater has triple protection and independent temperature limiter to ensure the safety of heating system |
|||||
Heating power 15kW adopts regulator, heating power output control adopts 4~20mA linear control. |
|||||
Refrigerating capacity |
Refers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures. |
||||
High temp cooling module |
The module can be cooled from 150 ℃ at high temperature. |
||||
Circulating pump flow |
Magnetic driving pump with LNEYA |
||||
Source 380V50HZ |
23kW max |
||||
Shape dimension |
1250*2350*1900 Same size of air-cooled water without outburst |
||||
Compression engine |
Emerson Valley Wheel Vortex flexible Compressor |
||||
Evaporimeter |
Adopting DANFOSS Plate Heat Exchanger / High strength Plate Heat Exchanger |
||||
Refrigeration Accessory |
Emerson / Danfoss brand dry filter, pressure control, oil separator, etc. |
||||
Expansion valve |
Danfoss thermal expansion valve / Emerson electronic expansion valve |
||||
Operation panel |
7-inch color touch screen, temperature curve display\ EXCEL data export |
||||
Safe guarding |
With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||
Cryogen |
R-404A/R507C |
||||
Reserved antifreeze interface inside the box |
G3/4 And globe valves |
||||
Water-cooled type W |
Type W is water cooled |
||||
Water-cooled condenser |
Double-pipe (heat) exchanger |
||||
Cooling water 32℃ |
6m³/H |
||||
Shell material |
Cold rolled sheet spray (Standard Colour 7035) |