High-Performance Low-Temperature Chiller Here is an Industrial Strength Water Cooling System [Low TEMP] for MS2 MACHINE. Including next-gen cooling tech to sustain pinpoint temperature settings for optimal performance and reliability.
Model |
HRB- 25 |
HRB- 55 |
HRB- 75 |
HRB- A10 |
HRB- A15(W) |
HRB- A25(W) |
HRB- A38W |
HRB- A60W |
|||||||||
Temp range |
0~100 ℃ |
||||||||||||||||
Control accuracy |
±0.5℃ |
||||||||||||||||
Flow control |
2~20L/min |
2~25L/min |
2~25L/min |
||||||||||||||
Heating power |
2.5KW |
5.5KW |
7.5KW |
10KW |
10KW(optional:15KW) |
15KW(optional:25KW) |
25KW(optional:38KW) |
38KW(optional:60KW) |
|||||||||
Cooling capacity (KW) |
100℃ |
2.5KW |
5.5KW |
7.5KW |
10KW |
15KW |
25KW |
38KW |
60KW |
||||||||
20℃ |
2.5KW |
5.5KW |
7.5KW |
10KW |
15KW |
25KW |
38KW |
60KW |
|||||||||
5℃ |
1.8KW |
3.8KW |
5.2KW |
7KW |
11KW |
18KW |
27KW |
42KW |
|||||||||
compressor |
HITACHI |
Emerson Valley Wheel Compressor |
|||||||||||||||
expansion |
Danfoss Thermal Expansion Valve/ Emerson Solenoid |
||||||||||||||||
oil distributor |
Emerson |
||||||||||||||||
Dry filter, Pressure |
Emerson/Danfoss |
||||||||||||||||
Interface size |
G3/4 |
||||||||||||||||
Refrigerant |
R 404A/R507C/R448A |
||||||||||||||||
Dimension cm |
45*85*130 |
55*95*175 |
55*95*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
145*205*205 |
|||||||||
Power max 380V 50HZ |
220V 4.5KW |
8.5KW |
11.5KW |
16KW |
18KW |
28KW |
40KW |
61KW |
|||||||||
Weight kg |
200 |
250 |
280 |
320 |
360 |
620 |
890 |
1300 |
|||||||||
Optional |
220V 60HZ three phase 460V 60HZ three phase |
||||||||||||||||
Optional |
220V 60HZ three phase 460V 60HZ three phase |
||||||||||||||||
Optional |
Automatic antifreeze filling system |
||||||||||||||||
Optional |
Automatic liquid recovery system |
Model |
HRB-7.5W/7.5 |
||||
Temperature Range |
-40℃~100℃ antifreeze |
-40℃~100℃ test chamber |
|||
Antifreeze Flow Control |
1L/min~25L/min ±0.2L/min |
/ |
|||
Antifreeze Pressure |
Measure and display the inlet and outlet pressure and display the pressure on the touch screen |
||||
Chamber volume |
Inside the upper box:2200*3220*1200mm Inside the lower box:2200*3220*1100mm |
||||
Heating Capacity |
7.5kW antifreeze |
14kW test chamber |
|||
Cooling Capacity |
135℃ |
7.5kW |
|||
20℃ |
7.5kW |
||||
0℃ |
7.5kW |
||||
-20℃ |
4.5kW |
||||
-35℃ |
1.8kW |
||||
test chamber |
Heating rate |
25~+100℃≥±2℃/Min |
|||
cooling rate |
25~-40℃≥1℃/Min |
||||
Antifreeze Temp Control Accuracy |
±0.5℃ |
||||
High & low temperature chamber temperature uniformity |
≤2℃ |
||||
Circulation Air Volume |
5000m3/h |
||||
Controller |
PLC controller, fuzzy PID control algorithm |
||||
Communication |
CAN |
||||
Device Internal Temperature Feedback |
The internal temperature of the equipment box, the condensation temperature of the refrigeration system, the suction temperature of the compressor, and the cooling water temperature (with water cooling equipment) |
||||
High temperature cooling module |
Cooling from a high temperature of 100°C |
||||
Circulation pump flow, pressure |
Magnetic drive pump |
||||
Power supply 380V50HZ |
Distribution main air switch model: EZD250E4225ELN |
||||
Dimensions mm |
2400*5600*2850 |
||||
Compressor |
Inverter compressor |
||||
Evaporator |
Plate heat exchanger |
||||
Refrigeration accessories |
Emerson/Danfoss brand dry filter, oil separator, etc. |
||||
Throttling mode |
Electronic expansion valve |
||||
Operation panel |
10-inch color touch screen, temperature curve displayEXCEL data export |
||||
Refrigerant |
R125/R507C/R404A |
||||
Protection |
Phase sequence and phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||
Internal reserved antifreeze interface |
ZG3/4 |
||||
Water cooled condenser |
Jacket/shell and tube heat exchanger |
||||
Cooling water @20°C |
25m3/H |
||||
Load bearing of inner bottom plate (tons) |
1.5 |
||||
Weight (tons) |
4.6 |
||||
Fulfill the standard |
GB/T 2423.1-2008 Test A: Low temperature test method |
||||
Fulfill the standard |
GB/T 2423.2-2008 Test B: Low temperature test method |
||||
Fulfill the standard |
GJB 150.3A-2009 High temperature test method |
||||
Fulfill the standard |
GJB 150.4A-2009 High temperature test method |
Model |
HRB-15W/15 |
||||
Temperature Range |
-40℃~100℃ antifreeze |
-40℃~100℃ test chamber |
|||
Antifreeze Flow Control |
1L/min~25L/min ±0.2L/min |
/ |
|||
Antifreeze Pressure |
Measure and display the inlet and outlet pressure and display the pressure on the touch screen |
||||
Chamber volume |
Inside the upper box:2200*3220*1200mm Inside the lower box:2200*3220*1100mm |
||||
Heating Capacity |
15kW antifreeze |
14kW test chamber |
|||
Cooling Capacity |
135℃ |
15kW |
|||
20℃ |
15kW |
||||
0℃ |
15kW |
||||
-20℃ |
10kW |
||||
-35℃ |
4kW |
||||
test chamber |
Heating rate |
25~+100℃≥±2℃/Min |
|||
cooling rate |
25~-40℃≥1℃/Min |
||||
Antifreeze Temp Control Accuracy |
±0.5℃ |
||||
High & low temperature chamber temperature uniformity |
≤2℃ |
||||
Circulation Air Volume |
5000m3/h |
||||
Controller |
PLC controller, fuzzy PID control algorithm |
||||
Communication |
CAN |
||||
Device Internal Temperature Feedback |
The internal temperature of the equipment box, the condensation temperature of the refrigeration system, the suction temperature of the compressor, and the cooling water temperature (with water cooling equipment) |
||||
High temperature cooling module |
Cooling from a high temperature of 100°C |
||||
Circulation pump flow, pressure |
Magnetic drive pump |
||||
Power supply 380V50HZ |
Distribution main air switch model: EZD400E4350ELK 4P350 |
||||
Dimensions mm |
2400*5600*2850 |
||||
Compressor |
Inverter compressor |
||||
Evaporator |
Plate heat exchanger |
||||
Refrigeration accessories |
Emerson/Danfoss brand dry filter, oil separator, etc. |
||||
Throttling mode |
Electronic expansion valve |
||||
Operation panel |
10-inch color touch screen, temperature curve displayEXCEL data export |
||||
Refrigerant |
R125/R507C/R404A |
||||
Protection |
Phase sequence and phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||
Internal reserved antifreeze interface |
ZG3/4 |
||||
Water cooled condenser |
Jacket/shell and tube heat exchanger |
||||
Cooling water @20°C |
25m3/H |
||||
Load bearing of inner bottom plate (tons) |
1.5 |
||||
Weight (tons) |
4.6 |
||||
Fulfill the standard |
GB/T 2423.1-2008 Test A: Low temperature test method |
||||
Fulfill the standard |
GB/T 2423.2-2008 Test B: Low temperature test method |
||||
Fulfill the standard |
GJB 150.3A-2009 High temperature test method |
||||
Fulfill the standard |
GJB 150.4A-2009 High temperature test method |