High - performance laboratory heater, designed and manufactured according to high - performance requirements. With advanced heating technology, it can quickly and accurately reach the set temperature, maintaining a stable thermal environment.
Model | HRB- 25 | HRB- 55 | HRB- 75 | HRB- A10 | HRB- A15(W) | HRB- A25(W) | HRB- A38W | HRB- A60W | |||||||||
Temp range | 0~100 ℃ | ||||||||||||||||
Control accuracy | ±0.5℃ | ||||||||||||||||
Flow control | 2~20L/min | 2~25L/min | 2~25L/min | ||||||||||||||
Heating power | 2.5KW | 5.5KW | 7.5KW | 10KW | 10KW(optional:15KW) | 15KW(optional:25KW) | 25KW(optional:38KW) | 38KW(optional:60KW) | |||||||||
Cooling capacity (KW) | 100℃ | 2.5KW | 5.5KW | 7.5KW | 10KW | 15KW | 25KW | 38KW | 60KW | ||||||||
20℃ | 2.5KW | 5.5KW | 7.5KW | 10KW | 15KW | 25KW | 38KW | 60KW | |||||||||
5℃ | 1.8KW | 3.8KW | 5.2KW | 7KW | 11KW | 18KW | 27KW | 42KW | |||||||||
compressor | HITACHI | Emerson Valley Wheel Compressor | |||||||||||||||
expansion | Danfoss Thermal Expansion Valve/ Emerson Solenoid | ||||||||||||||||
oil distributor | Emerson | ||||||||||||||||
Dry filter, Pressure | Emerson/Danfoss | ||||||||||||||||
Interface size | G3/4 | ||||||||||||||||
Refrigerant | R 404A/R507C/R448A | ||||||||||||||||
Dimension cm | 45*85*130 | 55*95*175 | 55*95*175 | 70*100*175 | 80*120*185 | 100*150*185 | 100*150*185 | 145*205*205 | |||||||||
Power max 380V 50HZ | 220V 4.5KW | 8.5KW | 11.5KW | 16KW | 18KW | 28KW | 40KW | 61KW | |||||||||
Weight kg | 200 | 250 | 280 | 320 | 360 | 620 | 890 | 1300 | |||||||||
Optional | 220V 60HZ three phase 460V 60HZ three phase | ||||||||||||||||
Optional | 220V 60HZ three phase 460V 60HZ three phase | ||||||||||||||||
Optional | Automatic antifreeze filling system | ||||||||||||||||
Optional | Automatic liquid recovery system |
Model | HRB-7.5W/7.5 | ||||
Temperature Range | -40℃~100℃ antifreeze | -40℃~100℃ test chamber | |||
Antifreeze Flow Control | 1L/min~25L/min ±0.2L/min | / | |||
Antifreeze Pressure | Measure and display the inlet and outlet pressure and display the pressure on the touch screen | ||||
Chamber volume | Inside the upper box:2200*3220*1200mm Inside the lower box:2200*3220*1100mm | ||||
Heating Capacity | 7.5kW antifreeze | 14kW test chamber | |||
Cooling Capacity | 135℃ | 7.5kW | |||
20℃ | 7.5kW | ||||
0℃ | 7.5kW | ||||
-20℃ | 4.5kW | ||||
-35℃ | 1.8kW | ||||
test chamber | Heating rate | 25~+100℃≥±2℃/Min | |||
cooling rate | 25~-40℃≥1℃/Min | ||||
Antifreeze Temp Control Accuracy | ±0.5℃ | ||||
High & low temperature chamber temperature uniformity | ≤2℃ | ||||
Circulation Air Volume | 5000m3/h | ||||
Controller | PLC controller, fuzzy PID control algorithm | ||||
Communication | CAN | ||||
Device Internal Temperature Feedback | The internal temperature of the equipment box, the condensation temperature of the refrigeration system, the suction temperature of the compressor, and the cooling water temperature (with water cooling equipment) | ||||
High temperature cooling module | Cooling from a high temperature of 100°C | ||||
Circulation pump flow, pressure | Magnetic drive pump | ||||
Power supply 380V50HZ | Distribution main air switch model: EZD250E4225ELN | ||||
Dimensions mm | 2400*5600*2850 | ||||
Compressor | Inverter compressor | ||||
Evaporator | Plate heat exchanger | ||||
Refrigeration accessories | Emerson/Danfoss brand dry filter, oil separator, etc. | ||||
Throttling mode | Electronic expansion valve | ||||
Operation panel | 10-inch color touch screen, temperature curve displayEXCEL data export | ||||
Refrigerant | R125/R507C/R404A | ||||
Protection | Phase sequence and phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | ||||
Internal reserved antifreeze interface | ZG3/4 | ||||
Water cooled condenser | Jacket/shell and tube heat exchanger | ||||
Cooling water @20°C | 25m3/H | ||||
Load bearing of inner bottom plate (tons) | 1.5 | ||||
Weight (tons) | 4.6 | ||||
Fulfill the standard | GB/T 2423.1-2008 Test A: Low temperature test method | ||||
Fulfill the standard | GB/T 2423.2-2008 Test B: Low temperature test method | ||||
Fulfill the standard | GJB 150.3A-2009 High temperature test method | ||||
Fulfill the standard | GJB 150.4A-2009 High temperature test method |
Model | HRB-15W/15 | ||||
Temperature Range | -40℃~100℃ antifreeze | -40℃~100℃ test chamber | |||
Antifreeze Flow Control | 1L/min~25L/min ±0.2L/min | / | |||
Antifreeze Pressure | Measure and display the inlet and outlet pressure and display the pressure on the touch screen | ||||
Chamber volume | Inside the upper box:2200*3220*1200mm Inside the lower box:2200*3220*1100mm | ||||
Heating Capacity | 15kW antifreeze | 14kW test chamber | |||
Cooling Capacity | 135℃ | 15kW | |||
20℃ | 15kW | ||||
0℃ | 15kW | ||||
-20℃ | 10kW | ||||
-35℃ | 4kW | ||||
test chamber | Heating rate | 25~+100℃≥±2℃/Min | |||
cooling rate | 25~-40℃≥1℃/Min | ||||
Antifreeze Temp Control Accuracy | ±0.5℃ | ||||
High & low temperature chamber temperature uniformity | ≤2℃ | ||||
Circulation Air Volume | 5000m3/h | ||||
Controller | PLC controller, fuzzy PID control algorithm | ||||
Communication | CAN | ||||
Device Internal Temperature Feedback | The internal temperature of the equipment box, the condensation temperature of the refrigeration system, the suction temperature of the compressor, and the cooling water temperature (with water cooling equipment) | ||||
High temperature cooling module | Cooling from a high temperature of 100°C | ||||
Circulation pump flow, pressure | Magnetic drive pump | ||||
Power supply 380V50HZ | Distribution main air switch model: EZD400E4350ELK 4P350 | ||||
Dimensions mm | 2400*5600*2850 | ||||
Compressor | Inverter compressor | ||||
Evaporator | Plate heat exchanger | ||||
Refrigeration accessories | Emerson/Danfoss brand dry filter, oil separator, etc. | ||||
Throttling mode | Electronic expansion valve | ||||
Operation panel | 10-inch color touch screen, temperature curve displayEXCEL data export | ||||
Refrigerant | R125/R507C/R404A | ||||
Protection | Phase sequence and phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | ||||
Internal reserved antifreeze interface | ZG3/4 | ||||
Water cooled condenser | Jacket/shell and tube heat exchanger | ||||
Cooling water @20°C | 25m3/H | ||||
Load bearing of inner bottom plate (tons) | 1.5 | ||||
Weight (tons) | 4.6 | ||||
Fulfill the standard | GB/T 2423.1-2008 Test A: Low temperature test method | ||||
Fulfill the standard | GB/T 2423.2-2008 Test B: Low temperature test method | ||||
Fulfill the standard | GJB 150.3A-2009 High temperature test method | ||||
Fulfill the standard | GJB 150.4A-2009 High temperature test method |