This recirculating water chiller provides reliable and efficient cooling solutions for diverse applications whether for cooling industrial machinery, for chemical processing, or in medical equipment applications, helping industries enhance productivity and product quality.
Model |
HRB- 25 |
HRB- 55 |
HRB- 75 |
HRB- A10 |
HRB- A15(W) |
HRB- A25(W) |
HRB- A38W |
HRB- A60W |
|||||||||
Temp range |
0~100 ℃ |
||||||||||||||||
Control accuracy |
±0.5℃ |
||||||||||||||||
Flow control |
2~20L/min |
2~25L/min |
2~25L/min |
||||||||||||||
Heating power |
2.5KW |
5.5KW |
7.5KW |
10KW |
10KW(optional:15KW) |
15KW(optional:25KW) |
25KW(optional:38KW) |
38KW(optional:60KW) |
|||||||||
Cooling capacity (KW) |
100℃ |
2.5KW |
5.5KW |
7.5KW |
10KW |
15KW |
25KW |
38KW |
60KW |
||||||||
20℃ |
2.5KW |
5.5KW |
7.5KW |
10KW |
15KW |
25KW |
38KW |
60KW |
|||||||||
5℃ |
1.8KW |
3.8KW |
5.2KW |
7KW |
11KW |
18KW |
27KW |
42KW |
|||||||||
compressor |
HITACHI |
Emerson Valley Wheel Compressor |
|||||||||||||||
expansion |
Danfoss Thermal Expansion Valve/ Emerson Solenoid |
||||||||||||||||
oil distributor |
Emerson |
||||||||||||||||
Dry filter, Pressure |
Emerson/Danfoss |
||||||||||||||||
Interface size |
G3/4 |
||||||||||||||||
Refrigerant |
R 404A/R507C/R448A |
||||||||||||||||
Dimension cm |
45*85*130 |
55*95*175 |
55*95*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
145*205*205 |
|||||||||
Power max 380V 50HZ |
220V 4.5KW |
8.5KW |
11.5KW |
16KW |
18KW |
28KW |
40KW |
61KW |
|||||||||
Weight kg |
200 |
250 |
280 |
320 |
360 |
620 |
890 |
1300 |
|||||||||
Optional |
220V 60HZ three phase 460V 60HZ three phase |
||||||||||||||||
Optional |
220V 60HZ three phase 460V 60HZ three phase |
||||||||||||||||
Optional |
Automatic antifreeze filling system |
||||||||||||||||
Optional |
Automatic liquid recovery system |
Model |
HRB-7.5W/7.5 |
||||
Temperature Range |
-40℃~100℃ antifreeze |
-40℃~100℃ test chamber |
|||
Antifreeze Flow Control |
1L/min~25L/min ±0.2L/min |
/ |
|||
Antifreeze Pressure |
Measure and display the inlet and outlet pressure and display the pressure on the touch screen |
||||
Chamber volume |
Inside the upper box:2200*3220*1200mm Inside the lower box:2200*3220*1100mm |
||||
Heating Capacity |
7.5kW antifreeze |
14kW test chamber |
|||
Cooling Capacity |
135℃ |
7.5kW |
|||
20℃ |
7.5kW |
||||
0℃ |
7.5kW |
||||
-20℃ |
4.5kW |
||||
-35℃ |
1.8kW |
||||
test chamber |
Heating rate |
25~+100℃≥±2℃/Min |
|||
cooling rate |
25~-40℃≥1℃/Min |
||||
Antifreeze Temp Control Accuracy |
±0.5℃ |
||||
High & low temperature chamber temperature uniformity |
≤2℃ |
||||
Circulation Air Volume |
5000m3/h |
||||
Controller |
PLC controller, fuzzy PID control algorithm |
||||
Communication |
CAN |
||||
Device Internal Temperature Feedback |
The internal temperature of the equipment box, the condensation temperature of the refrigeration system, the suction temperature of the compressor, and the cooling water temperature (with water cooling equipment) |
||||
High temperature cooling module |
Cooling from a high temperature of 100°C |
||||
Circulation pump flow, pressure |
Magnetic drive pump |
||||
Power supply 380V50HZ |
Distribution main air switch model: EZD250E4225ELN |
||||
Dimensions mm |
2400*5600*2850 |
||||
Compressor |
Inverter compressor |
||||
Evaporator |
Plate heat exchanger |
||||
Refrigeration accessories |
Emerson/Danfoss brand dry filter, oil separator, etc. |
||||
Throttling mode |
Electronic expansion valve |
||||
Operation panel |
10-inch color touch screen, temperature curve displayEXCEL data export |
||||
Refrigerant |
R125/R507C/R404A |
||||
Protection |
Phase sequence and phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||
Internal reserved antifreeze interface |
ZG3/4 |
||||
Water cooled condenser |
Jacket/shell and tube heat exchanger |
||||
Cooling water @20°C |
25m3/H |
||||
Load bearing of inner bottom plate (tons) |
1.5 |
||||
Weight (tons) |
4.6 |
||||
Fulfill the standard |
GB/T 2423.1-2008 Test A: Low temperature test method |
||||
Fulfill the standard |
GB/T 2423.2-2008 Test B: Low temperature test method |
||||
Fulfill the standard |
GJB 150.3A-2009 High temperature test method |
||||
Fulfill the standard |
GJB 150.4A-2009 High temperature test method |
Model |
HRB-15W/15 |
||||
Temperature Range |
-40℃~100℃ antifreeze |
-40℃~100℃ test chamber |
|||
Antifreeze Flow Control |
1L/min~25L/min ±0.2L/min |
/ |
|||
Antifreeze Pressure |
Measure and display the inlet and outlet pressure and display the pressure on the touch screen |
||||
Chamber volume |
Inside the upper box:2200*3220*1200mm Inside the lower box:2200*3220*1100mm |
||||
Heating Capacity |
15kW antifreeze |
14kW test chamber |
|||
Cooling Capacity |
135℃ |
15kW |
|||
20℃ |
15kW |
||||
0℃ |
15kW |
||||
-20℃ |
10kW |
||||
-35℃ |
4kW |
||||
test chamber |
Heating rate |
25~+100℃≥±2℃/Min |
|||
cooling rate |
25~-40℃≥1℃/Min |
||||
Antifreeze Temp Control Accuracy |
±0.5℃ |
||||
High & low temperature chamber temperature uniformity |
≤2℃ |
||||
Circulation Air Volume |
5000m3/h |
||||
Controller |
PLC controller, fuzzy PID control algorithm |
||||
Communication |
CAN |
||||
Device Internal Temperature Feedback |
The internal temperature of the equipment box, the condensation temperature of the refrigeration system, the suction temperature of the compressor, and the cooling water temperature (with water cooling equipment) |
||||
High temperature cooling module |
Cooling from a high temperature of 100°C |
||||
Circulation pump flow, pressure |
Magnetic drive pump |
||||
Power supply 380V50HZ |
Distribution main air switch model: EZD400E4350ELK 4P350 |
||||
Dimensions mm |
2400*5600*2850 |
||||
Compressor |
Inverter compressor |
||||
Evaporator |
Plate heat exchanger |
||||
Refrigeration accessories |
Emerson/Danfoss brand dry filter, oil separator, etc. |
||||
Throttling mode |
Electronic expansion valve |
||||
Operation panel |
10-inch color touch screen, temperature curve displayEXCEL data export |
||||
Refrigerant |
R125/R507C/R404A |
||||
Protection |
Phase sequence and phase failure protector, refrigerator overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||
Internal reserved antifreeze interface |
ZG3/4 |
||||
Water cooled condenser |
Jacket/shell and tube heat exchanger |
||||
Cooling water @20°C |
25m3/H |
||||
Load bearing of inner bottom plate (tons) |
1.5 |
||||
Weight (tons) |
4.6 |
||||
Fulfill the standard |
GB/T 2423.1-2008 Test A: Low temperature test method |
||||
Fulfill the standard |
GB/T 2423.2-2008 Test B: Low temperature test method |
||||
Fulfill the standard |
GJB 150.3A-2009 High temperature test method |
||||
Fulfill the standard |
GJB 150.4A-2009 High temperature test method |